Microcom 450 Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Tiskárny Microcom 450. Microcom 450 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 15
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
MICROCOM CORPORATION
LABEL DESIGN SOFTWARE
FOR MODELS
1100, 1400, 2000
2150, M450, M460
M650
LDS100/140/200/250/450/460/650
REV 2.2
NOVEMBER 11, 1988
©1988 Microcom Corporation, All Rights Reserved
Zobrazit stránku 0
1 2 3 4 5 6 ... 14 15

Shrnutí obsahu

Strany 1

MICROCOM CORPORATIONLABEL DESIGN SOFTWAREFOR MODELS1100, 1400, 20002150, M450, M460M650LDS100/140/200/250/450/460/650REV 2.2NOVEMBER 11, 1988©1988 Mic

Strany 2

*1 The default for these elements depends on the character generator used (CGN).*2 The default for this element depends on the text conversion

Strany 3

25 MSI 2 26 MSI 3 28 MSI Human readable type 1 29 MSI Human readable type 2 32 UPCA human read

Strany 4

CS CHARACTER SPACINGThis element determines the spacing between each character. Ifthis element is not used, then the default value for theselected c

Strany 5

Switch Bank One (Top set of switches)1 |Response to enquiry ------------> 1 22 | ------------------------3

Strany 6

‘SCG1DO’ FOR PRINTER WITH LDS SOFTWARE 88.06.18The following letters (NURL)

Strany 7

BARCODE GENERATORSCODE NURL CODE RATIO SPACING NO.1 C392 NU C39 2/1 1 3 NU C39 3/1 14

Strany 8

1. INTRODUCTIONThe Label Design Software (LDS) is a powerful and easy to use packagethat allows the user to create his own label formats. LDS supports

Strany 9

BS ^H Same as DEL but has another special function.LF ^J No effect.VT ^K Print a test label.FF ^L Print a blank label.DC3 ^S Instr

Strany 10

2.4 ^C PRINT MODEThe print mode instructs the print to start the print cycle.If the printer has not been instructed to print multiple copies thenonl

Strany 11

63 Load text mode control byte 0 Disable auto text mode entry and clear text control 1 Enable auto text mode entry (^B is optional)

Strany 12

96 Load keypad queuing number 0 Disable keypad queuing 1 Print first label then queue for remainder 2 3 Disab

Strany 13

These control codes are listed in order of priority. The SUBcharacter can only happen on the first poll after power up. Also theSUB character can be s

Strany 14

3.1 HEADER DESCRIPTIONA header is broken down into thirteen different elements. Theseelements contain information about the label. It is not necessar

Strany 15

label instead of the leading edge. If it is set to a value oftwo, then the printer will not wait on the gap detector. Instead,it prints